Key Features
TruAccuracy™ performance ensures the transducer meets its rated accuracy out of the box and is ready for installation with no additional calibration adjustments required.
Wide selection of differential pressure ranges
3-year warranty
Large LCD display with backlight
The exclusive patented Ashcroft SpoolCal® actuator provides in-place system calibration, thus adding great value when validating a process on-line or calibrating the unit
Field selectable outputs
Two programmable switch outputs, NPN or PNP
High overpressure limit
Adjustable display response time
Markets & Applications
HVAC-R
Comfort Control Systems
Velocity Pressure
Building Energy Management
Pharmaceuticals
Clean Room / Laboratory Pressurization
Critical Environments
Dampening
Update rate by firmware
Process Connection Style
Threaded
Barbed fitting
Accuracy
0.25% of span
0.5% of span
Pressure Type
Differential pressure
Stability
≤±0.25% span/year at reference conditions
Switch Style
NPN or PNP - Field programable
Ranges
Bidirectional: ±15 Pa ... ±5 kPa / ±0.05 in. H2O ... ±25 in. H2O
Unidirectional: 25 Pa ... 6 kPa / 0.1 in. H2O ... 25 in. H2O
Static Pressure
1.7 bar / 25 psi
Wetted Parts Material
Aluminum, Titanium, PBT, Buna, Glass, Gold, Silicone Rubber, Silicon, Silicone RTV & Brass. NOT FOR USE WITH LIQUIDS
Ingress Protection
IP67 / NEMA 4
Display
Digital local display with several options
Case or Body Material
Fire-retardant ABS
Electrical Termination
1/2 NPT female
Plastic cable gland
Process Connection Location
Lower
Mounting
Flush
Surface
DIN rail
Output Signal
4-20 mA (2-wire)
0-5 VDC (3-wire)
0-10 VDC (3-wire)
Many other voltage outputs
Equipped with a highly reliable and accurate sensing element, featuring the patented Ashcroft® Si-Glass™ sensor, Ashcroft offers a range of differential pressure transmitters specifically designed and developed for use in the cleanroom industry. Using an ultra-thin single crystal diaphragm, Ashcroft differential pressure transmitters offer inherent sensor repeatability and stability, making them stand out as highly accurate, long-term stable and reliable measurement instruments for cleanroom pressure monitoring.
The silicon diaphragm sensor is free of adhesives or other organic materials that are commonly used in differential pressure measurement technology and contribute to a drift in the measured value acquisition or a mechanical reduction in the measurement accuracy.
Ashcroft differential pressure transmitters incorporate the TruAccuracy™ specification. Ashcroft’s accuracy claim is based solely on terminal endpoint methodology and not on statistically derived accuracy claims’.
TruAccuracy™ means that Ashcroft differential pressure transmitters include zero offset, non-linearity, hysteresis, non-repeatability, zero offset and span adjustment error in their accuracy statement.
The user thus has a ready-to-install device at his disposal that does not require any initial calibration after installation. This considerably reduces the time and costs involved.
Other commercially available measuring devices usually do not include information on zero point deviation and span error in their accuracy specifications, so that these measurement errors (up to ±1.00%) must be added to the accuracy in order to achieve reliable performance characteristics.