Key Features
100% Helium leak tested
Class 10,000/ISO Class 7 or Class 100/ISO Class 5 cleanroom packaged and double bagged
316L stainless steel wetted parts
Lower and back mount connections
Markets & Applications
Machine Automation
High-Purity Gas Delivery Systems
Gas Sticks
Process gas analyzers
Semiconductor
Mounting
Stem
Surface Finish
Tube and fitting < 1.6 μm Ra (<0.25 μm Ra option)
Process Connection Style
Threaded
Case Style
Open front case
Dial Size
63 mm
50 mm
Accuracy
1.6% of span (class 1.6)
2.5% of span (class 2.5)
Ranges
Compound
1 ... 210 bar / 15 ... 3000 psi
Wetted Parts Material
Stainless steel 316L (1.4404)
Case or Body Material
Stainless steel 304 (1.4301)
Process Connection Size
¼ NPT
G ¼
9⁄16-18 UNF (compatible with 1⁄4 VCR®) swivel male or female
Process Connection Location
Lower
Lower back
Centre back
Equipped with a highly reliable and accurate sensing element, featuring the patented Ashcroft® Si-Glass™ sensor, Ashcroft offers a range of differential pressure transmitters specifically designed and developed for use in the cleanroom industry. Using an ultra-thin single crystal diaphragm, Ashcroft differential pressure transmitters offer inherent sensor repeatability and stability, making them stand out as highly accurate, long-term stable and reliable measurement instruments for cleanroom pressure monitoring.
The silicon diaphragm sensor is free of adhesives or other organic materials that are commonly used in differential pressure measurement technology and contribute to a drift in the measured value acquisition or a mechanical reduction in the measurement accuracy.
Ashcroft differential pressure transmitters incorporate the TruAccuracy™ specification. Ashcroft’s accuracy claim is based solely on terminal endpoint methodology and not on statistically derived accuracy claims’.
TruAccuracy™ means that Ashcroft differential pressure transmitters include zero offset, non-linearity, hysteresis, non-repeatability, zero offset and span adjustment error in their accuracy statement.
The user thus has a ready-to-install device at his disposal that does not require any initial calibration after installation. This considerably reduces the time and costs involved.
Other commercially available measuring devices usually do not include information on zero point deviation and span error in their accuracy specifications, so that these measurement errors (up to ±1.00%) must be added to the accuracy in order to achieve reliable performance characteristics.