Key Features
SIL 3 Capable
Wide selection of switch elements
UL, CSA and CE approved
Internal setpoint locking screw
Direct or remote reading thermal systems
Adjustable setpoints from 0 ... 100% of range
Markets & Applications
HVAC-R
Chemical and Petrochemical
Energy
Food and Beverage
Oil and Gas
Machine Automation
Hydrogen and Technical Gases
Pharmaceuticals
Pulp and Paper
Pumps and Compressors
Water and Wastewater
Case or Body Material
Epoxy coated aluminium
Stem length
2¾ ... 24˝ (70 ... 610 mm)
Process Connection Location
Lower
Line Length
Capillary lengths from 5 ... 25 ft (1.5 ... 7.5 m), consult factory for longer lengths
Mounting
Stem
Surface
2" pipe mounting
Process Connection Style
Threaded
Accuracy
1% of span
Electrical Termination
3/4 NPT female
1/2 NPT female
M20x1.5 female
Plastic cable gland
Hirschmann EN 175301-803 Form A
Switch Style
Microswitch DPDT
Microswitch SPDT
Ranges
-40 ... 400°C
Wetted Parts Material
Stainless steel 316 (1.4401)
Process Connection Size
½ NPT
Ingress Protection
IP66 / NEMA 4X
Setpoint
Single setpoint - Field adjustable
Deadband Fixed
Deadband limited adjustable
Single setpoint - Factory set
Equipped with a highly reliable and accurate sensing element, featuring the patented Ashcroft® Si-Glass™ sensor, Ashcroft offers a range of differential pressure transmitters specifically designed and developed for use in the cleanroom industry. Using an ultra-thin single crystal diaphragm, Ashcroft differential pressure transmitters offer inherent sensor repeatability and stability, making them stand out as highly accurate, long-term stable and reliable measurement instruments for cleanroom pressure monitoring.
The silicon diaphragm sensor is free of adhesives or other organic materials that are commonly used in differential pressure measurement technology and contribute to a drift in the measured value acquisition or a mechanical reduction in the measurement accuracy.
Ashcroft differential pressure transmitters incorporate the TruAccuracy™ specification. Ashcroft’s accuracy claim is based solely on terminal endpoint methodology and not on statistically derived accuracy claims’.
TruAccuracy™ means that Ashcroft differential pressure transmitters include zero offset, non-linearity, hysteresis, non-repeatability, zero offset and span adjustment error in their accuracy statement.
The user thus has a ready-to-install device at his disposal that does not require any initial calibration after installation. This considerably reduces the time and costs involved.
Other commercially available measuring devices usually do not include information on zero point deviation and span error in their accuracy specifications, so that these measurement errors (up to ±1.00%) must be added to the accuracy in order to achieve reliable performance characteristics.