Key Features
316L stainless steel enclosure provides uncompromising protection
Adjustable setpoints from 15% ... 100% of range
Wide selection of switch elements
Designed for easy field installation and wiring of microswitches
Markets & Applications
Water and Wastewater
Food and Beverage
Filtration Monitoring
Pharmaceuticals
Pulp and Paper
Ranges
75 ... 375 mbar / 30 ... 150 in. H2O
2 ... 28 bar / 30 ... 400 psi
Pressure Type
Differential pressure
Wetted Parts Material
Stainless steel 316L (1.4404)
Buna-N®
Teflon®
Viton®
Static Pressure
PN100
0.375 ... 70 bar / 5.4 ... 1000 psi
Ingress Protection
IP66 / NEMA 4X
Case or Body Material
Stainless steel 316L (1.4404)
Setpoint
Single setpoint, adjustable deadband
Single setpoint, fixed deadband
Two independent setpoints, fixed deadband
Process Connection Location
In-line
Bottom/side
Mounting
Stem
Surface
2" pipe mounting
Process Connection Style
Threaded
Accuracy
1% of span
Switch Style
Microswitch SPDT
Microswitch DPDT
Electrical Termination
3/4 NPT female
1/2 NPT female
M20x1.5 female
Cable gland Ex d
Equipped with a highly reliable and accurate sensing element, featuring the patented Ashcroft® Si-Glass™ sensor, Ashcroft offers a range of differential pressure transmitters specifically designed and developed for use in the cleanroom industry. Using an ultra-thin single crystal diaphragm, Ashcroft differential pressure transmitters offer inherent sensor repeatability and stability, making them stand out as highly accurate, long-term stable and reliable measurement instruments for cleanroom pressure monitoring.
The silicon diaphragm sensor is free of adhesives or other organic materials that are commonly used in differential pressure measurement technology and contribute to a drift in the measured value acquisition or a mechanical reduction in the measurement accuracy.
Ashcroft differential pressure transmitters incorporate the TruAccuracy™ specification. Ashcroft’s accuracy claim is based solely on terminal endpoint methodology and not on statistically derived accuracy claims’.
TruAccuracy™ means that Ashcroft differential pressure transmitters include zero offset, non-linearity, hysteresis, non-repeatability, zero offset and span adjustment error in their accuracy statement.
The user thus has a ready-to-install device at his disposal that does not require any initial calibration after installation. This considerably reduces the time and costs involved.
Other commercially available measuring devices usually do not include information on zero point deviation and span error in their accuracy specifications, so that these measurement errors (up to ±1.00%) must be added to the accuracy in order to achieve reliable performance characteristics.